Product description
• Non-dimmable 1-channel ECG for constant current operation of LED modules
• Non-SELV output voltage
• Very high efficiency of up to 93 % (100 % load)
• For use in luminaires of protection class I
• ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload
• Suitable for direct current operation and application in combination with central battery installations
• Certified as thermally protected device
• Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference
• Nominal service lifetime with a failure rate ≤ 10 %:
30,000 h at tc = tc,max
50,000 h at tc = tc,max - 10K
- IP Class
- IP20
- Constant Current
- 350mA
Product details
LCS135-70FX-01/220-240 / 10116496
Output currents: 350mA
Output voltage /channel: 60 ... 190V
Total output power: 21 ... 66,5W
ECG efficiency: 93%
Mains voltage supply
Rated voltage range 220 ... 240 V
Max. permanent voltage range (continuous) 198 ... 264 V
Rated frequency 0 / 50 ... 60 Hz
Battery operation
Voltage range for continuous operation 198 ... 278 VDC
Lowest limiting value for temporary operation 176 VDC / 0.5 h
Mains overvoltage
Overvoltage protection 350 VAC / 2 h
Automatic switch-off of the LEDs at appr. 320 VAC
Protection against voltage peaks
Voltage peaks L - N 1 kV
Voltage peaks L/N -PE 2 kV
Starting time
Time to 100% luminous fl ux < 0.5 s
Total harmonic distortion (THD)
At 100% load to ECG-output < 10 %
Output data
Tolerance of output current +/- 10 %
Max. ripple of output current +/- 20 %
Max. wire length to LED module 2 m
Galvanic separation to mains input no
Protection functions output side
Overload operation yes; ECG switch-off, restart after mains interruption
Short-circuit operation yes; limitation of the output current
Open-circuit operation yes; ECG switch-off, restart after mains interruption
Lifetime
Operation at tc = tc,max 30,000 h; failure rate ≤ 10 %
Operation at tc = tc,max - 10 K 50,000 h; failure rate ≤ 10 %
Connection terminals
Type Terminal with release hole 1)
Wire cross section 0.5 mm² - 1.5 mm²
Wire stripping length 8 mm - 9 mm
Thermal protected device
Max. sureface temperature acc. to EN 61347-1/C5e + 110° C
Degree of protection
Degree of protection of ECG housing IP 20
Shipping costs
- PostNord MyPack Collect
- 7,50 €
- Delivery in 1-3 business days. Package will be kept for 7 days at the pickup point.
- PostNord MyPack Home Finland
- 19,00 €
- Door to door service, delivery in 2-6 business days.
- PostNord Finland Parcel (For companies)
- 12,00 €
- Delivery in 1-3 business days. Door to Door service for business address.
- Matkahuolto Lähellä-package
- 8,50 €
- Delivery usually in 2-5 business days. The package will be kept for 7 days in the pick up location.
- Posti Standard Delivery Finland
- 9,00 €
- Delivery in 2-5 business days.
- DB Schenker Pick Up Package
- 8,50 €
- Delivery in 2-5 business days.
- Pick Up from Warehouse
- 0,00 €
- Pick up from warehouse (Rajakivenkatu 8, 20740 Turku) between 9AM-3PM on weekdays (closed on weekends and on national holidays). Products are ready for pick up in 3 hours.