12.5W ~ 95W 2x250..900mA DALI dimmable LED driver

BAG Electronics

12.5W ~ 95W 2x250..900mA DALI dimmable LED driver

Price
63,23
Availability
Temporarily out of stock
Product stock balance
0 pcs

Product description

BAG ICD290-100LS-01/220-240/DALI

  • Dimmable 2 channel ECG for constant current operation of LED modules
  • Programmable functions* for modification according to specific applications
    • Individual output current in range 250-900 mA per channel-Dimming method: selection between Amplitude, PWM (500 Hz) and Mixed Mode
    • Compensation of LED degradation during operating time
    • Selection between 1 and 2 DALI addresses
    • Temperature-dependent control of output currents
    • Adjustment of output currents by means of resistors
  • Detect & React interface: analogue interface for connecting sensors e.g. for temperature or light detection
  • SELV equiv. output voltage ≤ 60 VDC
  • Very high efficiency of up to 90 % (100 % load)
  • Soft start and low output current ripple
  • For use in luminaires of protection class I
  • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit, underload or overload
  • Suitable for direct current operation and application in combination with central battery installations
  • Push-DIM function of DALI interface: switching and dimming via push-button
  • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference
  • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc = tc,max
    * Programming via software ZITARES 360
    IP Class
    IP20
    Constant Current
    250mA
    900mA

    Product details

    Output voltage /channel: 25-53V
    Output currents: 2 x 250 ... 900mA
    Total output power: 12.5 ... 95 W
    ECG efficiency: 91%


    General technical data

    Mains voltage supply

    Rated voltage range 220 ... 240 V

    Max. permanent voltage range (continuous) 198 ... 264 V

    Rated frequency 0 / 50 ... 60 Hz

    Battery operation

    Voltage range for continuous operation 198 ... 278 VDC

    Lowest limiting value for temporary operation 176 VDC / 0.5 h

    Mains overvoltage

    Overvoltage protection 350 VAC / 2 h

    Automatic switch-off of the LEDs at appr. 350 VAC

    Protection against voltage peaks

    Voltage peaks L - N 1 kV

    Voltage peaks L/N -PE 2 kV

    Starting time

    Time to 100% luminous fl ux < 0.5 s

    Total harmonic distortion (THD)

    At 100% load to ECG-output < 10 %

    Output data

    Tolerance of output current +/- 5 %

    Max. ripple of output current +/- 10 %

    Max. wire length to LED module 2 m

    Galvanic separation to mains input yes, test voltage 3.75 kV

    Protection functions output side

    Overload operation yes; limitation of output voltage and reduction of output current

    Underload / Short-circuit operation yes; output channel swich-off in case of permanent operation,

    restart after mains interruption

    Open-circuit operation yes; output voltage max. 60 VDC (SELV equiv.)

    Hot plug-in allowed; protection of LED module has to be ensured

    Dimming operation and interface

    Overvoltage protection of interface 264 VAC

    Galvanic separation to output side yes, test voltage 3.75 kV

    Stand-by power losses ≤ 0.5 W

    Dimming range for luminous fl ux 1 ... 100 %

    Dimming technology 500 Hz (PWM) or Amplitude or Mixed Mode 2)

    Max. number of ECG for Push-Dim control 25

    Detect & React interface

    Overvoltage protection of interface 60 VDC

    Range of contral voltage 0 ... 10 VDC

    Range of resistance detection (resolution) 0 ... 10 kΩ (100 Ω)

    Max. control current 4 mA

    Connection terminals

    Type 90°-terminal with key 1)

    Wire cross section 0.5 mm² - 1.5 mm²

    Wire stripping length 7.5 mm - 8.5 mm

    Thermal protected device

    Max. sureface temperature acc. to EN 61347-1/C5e + 110° C

    Degree of protection

    Degree of protection of ECG housing IP 20

    1) Terminals and ECG construction are designed for an automatic wiring with robots

    2) See page 8 ‟dimming methods“ for futher interformation


    Temperatures

    Ambient (ta) – 25 °C ... +50 °C 

    Case (tc) max. + 75 °C

    Lifetime

    Operation at tc = tc,max 50,000 h; failure rate ≤ 10 %
    Operation at tc = tc,max - 10 K 100,000 h; failure rate ≤ 10 %

    Shipping costs

    PostNord MyPack Collect
    7,50 €
    Delivery in 1-3 business days. Package will be kept for 7 days at the pickup point.
    PostNord MyPack Home Finland
    19,00 €
    Door to door service, delivery in 2-6 business days.
    PostNord Finland Parcel (For companies)
    12,00 €
    Delivery in 1-3 business days. Door to Door service for business address.
    Matkahuolto Lähellä-package
    8,50 €
    Delivery usually in 2-5 business days. The package will be kept for 7 days in the pick up location.
    Posti Standard Delivery Finland
    9,00 €
    Delivery in 2-5 business days.
    DB Schenker Pick Up Package
    8,50 €
    Delivery in 2-5 business days.
    Pick Up from Warehouse
    0,00 €
    Pick up from warehouse (Rajakivenkatu 8, 20740 Turku) between 9AM-3PM on weekdays (closed on weekends and on national holidays). Products are ready for pick up in 3 hours.

     

     

     

     
     
     
     
     

     

     
     
     
     
     

     

     
     
     
     
     

     

     
     
     
     
     

     

     
     
     
     
     

     

     
     
     
     

    Gift card